Industries>Explosive atmospheres>ASCO Numatics & ATEX

ASCO Numatics & ATEX


ASCO Numatics equipment concerned by this directive:

The ATEX directive applies to electrical and non-electrical apparatus.

  • The all solenoid valve, body and coil, is ATEX certified
  • A pneumatic valve with integrated pilot can be compared to a solenoid valve; the complete product has to be ATEX certified
  • A pneumatic valve with separate pilot (i.e. with a CNOMO pilot valve) needs two certifications: one for the CNOMO solenoid valve, one for the pneumatic valve
  • The ATEX certification is needed for non-electrical apparatus: filters, regulators, lubricators, air operated valves, cylinders.

See our on-line ATEX catalogue

go to the top of page

Equipment marking:

Marking according to EN 60079-1 Marking according to EN 61241-1
Marking according to EN 61241-18 Marking according to EN 13463-5

Marking samples

Serie NK solenoid head

ATEX label for solenoid head

Standardised cylinder

ATEX label for pneumatic product
retour haut de page

Gases groups

Groups Gas Ignition
temperatures
Temperatures classes
T1 T2 T3 T4 T5 T6
I methane (firedamp)
II A acetone
acetic acide
ammonia
ethane
methylene chloride
methane (CH4)
carbon monoxyde
propane
540 °C
485 °C
630 °C
515 °C
556 °C
595 °C
605 °C
470 °C
n-butane
n-butyl
365 °C
370 °C
n-hexane 240 °C
acetaldehyde
ethyl ether
140 °C
170 °C
ethyl nitrite 90 °C
B ethylene
ethyl oxyde
425 °C
429 °C - 440 °C
hydrogen sulfide 270 °C
C acetylene (C2H2) 305 °C
carbon disulphide (CS2) 102 °C
hydrogen (H2) 560 °C

Degrees of protection for enclosures

Tableau de classification des degrés de protection IP

Goto the top of pageConformity documents supplied by ASCO Numatics:

  • With products
    • declaration of CE conformity
    • Installation & maintenance sheet
  • On demand
    • EC-type-examination certificate
    • Notification of the Quality Assurance System

[General information] - [Groups and zones] - [ASCO Numatics & ATEX]
[Products & certificates] - ["ia" compatibility chart] - [Online catalogue] - [FAQ]

© Copyright ASCO Numatics 2003 - 2009